Operation Of HPLC (Agilent)

To lay down the procedure for operation of HPLC (Agilent) configuration. This SOP is applicable for operation of HPLC (Agilent) in Quality control department. Connect the instrument to 230 volts A/C power supply. Switch on the instrument by pressing switch to turn on the variable wavelength detector, auto sampler, pump and vacuum degasser one by one.

https://ichapps.com/qms/view/operation-of-hplc-agilent

continue reading
1 visits |0 Comments

Operation of Visible Melting Range Apparatus (Lab India)

To lay down the procedure for operation of visible melting range apparatus. This SOP is applicable in melting range apparatus Quality control department. Connect the instrument 230 volts A/C power supply and switch on the instrument and TV monitor. The LCD monitor will automatically on by one display as follows. Now after press ‘ENTER’ key instrument gives Beep and returns to Program screen.

https://ichapps.com/qms/view/operation-of-visible-melting-range-apparatus-lab-india

continue reading
1 visits |0 Comments

Operation of High Performance Liquid Chromatograph

To lay down the procedure for operation of HPLC (Waters 600E connected with 2487 detector/Waters 1525 with 2487 detector) configuration. This SOP is applicable for operation of HPLC (Waters 600E with 2487 detector/Waters 1525 with 2487 detector) in Quality control department. Connect the instrument to 230 volts A/C power supply. Switch on the 600 E pump/1525 pump.

https://ichapps.com/qms/view/operation-of-high-performance-liquid-chromatograph-waters-600e-with-2487-detector-or-waters-1525-with-2487-detector

continue reading
1 visits |0 Comments

Operation of Metrohm 701 KF Titrino

posted by ichappsseo 12 hours ago
tags: Metrohm 701 KF Titrino cond mode start enter

To lay down the procedure for operation of metrohm – 701 KF titrino. This procedure is applicable in Quality Control department. Switch on the instrument at the rear side of KF titrino. “KFT” shall display. Fill the reservoir with AR grade methanol. Fill the reagent bottle located on the exchange unit with KF reagent. Switch on the 703 Ti stand to on the stirrer.

https://ichapps.com/qms/view/operation-of-metrohm-701-kf-titrino

continue reading
1 visits |0 Comments

Operation Of Jasco P 1030 Polarimeter

To lay down the procedure for operation of JASCO–P–1030 POLARIMETER. This procedure is applicable for Quality Control Department (Block-D). Switch on the main instrument, which is placed left corner of the rear side. switch on the computer. Double click on JASCO – P – 1030 Icon on the desktop. A Spectra Manager window will appear on the screen. Double click on standard menu.  A initialization dialogue box will appear on the screen. Initialization takes about 5 minutes.

https://ichapps.com/qms/view/operation-of-jasco-p-1030-polarimeter

continue reading
1 visits |0 Comments

Operation And Calibration Of Malvern Mastersizer 2000

To lay down the procedure for operation and calibration malvern mastersizer – 2000. This SOP is applicable in quality control department. Switch on the accessories. Switch on the instrument, which is placed on the end of the panel. Switch on the computer and start the software by double click on the Mastersizer Malvern 2000 Icon on the desktop. Enter the user name and click O.K.

https://ichapps.com/qms/view/operation-and-calibration-of-malvern-mastersizer-2000

continue reading
1 visits |0 Comments

Operation Of Bandelin Sonorex Sonicator

To lay down the procedure for operation of Bandelin Sonorex - Sonicator. This procedure is applicable in Quality Control department. Check whether the side knob is closed. This knob is opened for draining the water from the instrument and kept closed while filling the water in the instrument and when the instrument is in use. Open the top lid and check the level of water. The optimum level is at least 2/3 height of the vessel.

https://ichapps.com/qms/view/operation-of-bandelin-sonorex-sonicator

continue reading
1 visits |0 Comments

Operation Of Merck Digital Burette

To lay down the procedure for operation of Merck Digital Burette. This procedure is applicable for Quality Control department. Fix the Burette to the Bottle containing required titrant as per STP. Switch on the Burette by pressing the upper on/off part of the on/off – Clear button. The display is 00.00.  If some other reading is displayed, then press the lower clear part of the on/off – clear button.

https://ichapps.com/qms/view/operation-of-merck-digital-burette

continue reading
1 visits |0 Comments

Operation of Titrino 794 Basic Titrino

To lay down the procedure for operation of Metrohm 794 Basic Titrino. This procedure is applicable for Quality Control department. Switch on the Instrument and the PC. Double Click on the Tinet 2.5 Icon. Metrohm Tinet window appears on the screen. Click Methods on Metrohm Tinet window. Go to File / New. A window appears with two Icons. First Icon is start Icon. Second Icon is Edit Icon with three dots on it. Select Titration / DET or MET (Mode of titration) / U or pH (Measured quantity) and Click.

https://ichapps.com/qms/view/operation-of-titrino-794-basic-titrino

continue reading
1 visits |0 Comments

Operation of Thermolab Oven

To lay down the procedure for operation of THERMOLAB – Oven. This procedure is applicable in Quality Control department. Switch on the Mains switch. For setting the required temperature, in the temperature indicator, press the upward key to increase the temperature and press the downward key to decrease the temperature. The temperature changes are highlighted in green color reading that is meant for set value (SV).

https://ichapps.com/qms/view/operation-of-thermolab-oven

continue reading
1 visits |0 Comments
[]